Omega Vehicle Security OMB-NETSCAN 1500 User Manual Page 187

  • Download
  • Add to my manuals
  • Print
  • Page
    / 256
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 186
Appendix A
API Command Reference
NetScan Users Manual A-47
Stop Scan Pointer
: This field represents the location in the current read block that the stop event
occurred. This pointer will always be relative to the trigger point with the trigger point always oriented at
location
0
. Since the stop event must always occur after the trigger event this pointer will always be
greater than
0
. If the stop event has not yet occurred at the time of the
U6
query, this field will have
the value of
-0999999
.
Stop Time Stamp
: This field represents the Time/Date that the stop event occurred for the current
read block. This field takes on the same format as other time/date stamp fields described elsewhere in
this manual. If the stop event has not yet occurred at the time of the
U6
query, then this field will have
the value
00:00:00.00,00/00/00
.
End Scan Pointer
: This field represents the location in the current read block that the end scan
occurred. This pointer will always be relative to the trigger point with the trigger point always oriented at
location
0
. Since the end scan must always occur after the trigger event this pointer will always be
greater than
0
. If the end scan has not yet occurred at the time of the
U6
query, this field will have the
value of
-0999999
. This field will always be the same as the Stop Scan Pointer unless a post-stop
count is specified (
Y
command) in which case the End Scan Pointer will be greater than the Stop Event
Pointer by the value of the post-stop count.
Block Status
: This field represents the status of the current read block. If the current read block is not
yet completely written then the value of this field will be
00
. If the current read block has been
completely written and has terminated normally the value will be
01
. If, however, the current read
block has prematurely terminated (because of user intervention) the value will be
02
.
Note: Trigger blocks are not assigned a trigger block number per se. The trigger block numbers referred to
in the
U6
examples (in
Appendix D
are relative to the read and write blocks, respectively.
U7
: Returns the input channel to digital output channel assignments in the form
A? Achan,output
for each
channel that is currently assigned to a digital output.
U8
: Reads the current configuration settings for each channel configured in the unit. This command returns the
same information in as the
C?
command except that it returns it for all channels which are configured.
U9
: Read the Digital Inputs. This command will read the current state of the digital inputs. This function is
performed by reading each of the eight digital inputs, converting each input to a binary (high is
1
and low is
0
)
and converting that aggregate binary 8-bit number into a decimal number. The decimal number is then returned
as the response
nnn
where it has the following form:
000
nnn
255
.
U10
: Queries the installed memory option. This command will return the amount of memory installed (in
Kbytes). The possible responses are:
00256
- 256 Kbyte option
04096
- 4 Meg option
01024
- 1 Meg option
08192
- 8 Meg option
U11
: Queries all channels having programmed valid alarm setpoints. The response is
CCC,A,CCC,A,CCC,A
where:
CCC
is a channel number in 3-didgit format, and
A
is the alarm state with
0
indicating not in alarm state, and
1
indicating in an alarm state. An example of a response in which channel 1
is the only channel in an alarm state is as follows:
001,1,002,0,003,0
U12
: Reads the last calibration time/date stamp. The response is the
#
(number sign, to distinguish it from
other time/date stamps) appended with the time/date of the last calibration. For example:
#12:31:01.20,04/24/93
U13
: Queries the last scan read.
U14
: Queries the card type. Returns card ID for each card slot. Valid card IDs for use with NetScan are:
-1
- Card not installed
16
- TC/Volts card
17
- High volts card
Note: This command can only be issued when all channels are in an unconfigured state. If any channel is
configured, the system will issue a command conflict error in response to the
U14
command. Also
see
QC?
And
C
commands.
U15
: Queries the product information. The response to this command is the current product information
including revision levels.
U16
: This command queries the measuring mode parameters defined by the Set Measuring Mode (
M#
), Set
Burst Mode Frequency (
F#
), and Set Averaging Weight (
W#
) commands. The response has the following form:
M#modeF#freqW#wt
Page view 186
1 2 ... 182 183 184 185 186 187 188 189 190 191 192 ... 255 256

Comments to this Manuals

No comments