Omega Vehicle Security OMB-NETSCAN 1500 User Manual Page 61

  • Download
  • Add to my manuals
  • Print
  • Page
    / 256
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 60
NetScan Users Manual ChartView Software Reference 4-23
Device
Interface
Setup IEEE 488
The IEEE 488 Setup dialog box appears. Valid addresses are 0 to 30. DIP switch settings must agree
with this setup. For ChartScan, an IEEE 488 interface card is required for use of IEEE 488 interface.
NetScan devices can not make use of the IEEE 488 interface.
When using ChartView with IEEE 488 applications, you must make use of an IOtech Driver 488/W31, /W95,
or /WNT when made available. In addition, the device must be configured in the Driver 488 and be named
WAVE.
NetScan devices can not make use of the IEEE 488 interface.
Setup
RS-232/422
The RS-232/422 Setup dialog box appears. If Yes is chosen for modem, the RS-232/422 Setup window
changes, allowing you to cancel your
call waiting
service by entering your cancellation code and your modem
phone number. The Cancel Code pull-down list provides three common code options. Instead of using a
code from the list, you can type in the desired code. Note that the device DIP switch settings must match
those entered in the text boxes.
Comm Port
1-16
Baud Rate
300, 600, 1200, 2400, 4800, 9600, 19200
Parity
None, Odd, or Even
Handshaking
None or RTS/CTS
Modem
No or Yes
Cancel Codes
for
Call Waiting
*70, 70#, 1170, or type in other acceptable code
Page view 60
1 2 ... 56 57 58 59 60 61 62 63 64 65 66 ... 255 256

Comments to this Manuals

No comments