NetScan Users Manual,
11-06-98
PostView 5-5
Channel Information Region
By clicking on the up or down arrows (
σ
, or
τ
) by the channel selection box (item 11), you can select one
channel (of a maximum of 4 overlapping channels) that were assigned to that chart. You could then observe
the chart-related information for that specific channel. You can also select a new channel for the
information region by placing the cursor in (or tabbing over to) the Center or Units/Div fields and then
pressing PageUp or PageDown. This is particularly useful when your main window has been re-sized such
that the channel selection boxes are not visible.
The following list identifies the various areas of the region.
(10) Chart Max. Scale Value (Grid Limit Line)
(11) Channel Selection (Of charts available channels)
(12) Multiply (x2)
(13) Value at Marker
(14) Center(Value at chart mid-line)
(15) Units/Division (Provides the vertical increment of one
grid box.)
(16) Chart Min. Scale Value (Grid Limit Line)
(17)
Divide (
÷
2)
(22) Time at Marker
Multiply and Divide Buttons (12 & 17) - In addition to reading channel values, you can increase or
decrease the size of the selected channels chart. This is accomplished with the Multiply (12) and
Divide (17) push buttons. The Multiply push-button effectively increases the size of the selected channel’s
chart by a factor of 2, while automatically adjusting the charts high and low values (items 10 and 16).
Aside from clicking on the Multiply/Divide controls, you can use your keyboard spacebar to control this
feature once the button (12 or 17) is selected. Selection may be with mouse, or by tabbing over to the
control.
Making changes to a channels chart parameters does not affect the parameters of the other channels, with
the following exception: Holding the keyboards control key down while adjusting either spinner (
σ
/
τ
) for
center (item 14), or spinner for units/div (item 15) causes the parameter change to apply to all channels
displayed for the chart, not just the currently selected channel display. This feature applies to the spinners
and keyboard up and down arrow keys, but not to the text input.
Value at Marker (13) - is the charted channel value at the marker position. Item (22) indicates the time
this value was read.
Center Control (14) - changes the value of the selected channels chart centerline. Changing the value of
center results in an automatic change of the charts high and low end values (items 10 and 16), and possibly
an automatic change of the units/div (item 15). Aside from using the center spinner controls to change
center, you can change the center value by placing the mouse cursor in (or tabbing over to) the field and
then either typing in the desired value, or using the PC keyboard up and down arrow control keys.
Units/div (15) - The units in units/div
(15) can be °C, °F, °K, °R, mV, or V. The division referenced is one
vertical grid. In the example above for Channel 1, each vertical grid increment represents 0.1231°C per
division. Changing the units/division spinner controls (
σ
/
τ
) will result in an automatic adjustment of the
max scale and min scale values (items 10 and 16). Aside from using the units/div triangular controls to
change the value, you can change units/div from the Display Configuration Setup dialog box as described
on page 5-14.
Time at Marker (22) - is the time at the marker position. It is also the time that the indicated chart value
(13) was read.